- Article name
- Compensating cable
- Conductor material
- NiCr-Ni, type KCA (IEC 60584-3)
- Wire insulation
- FEP
- Wire colours
- Green (+), white (-)
- Test voltage wire insulation
- 600 V
- Stranding
- Stranded= 120 mm, ±15%
- Sheath insulation
- Silicon
- Oversheath colour
- Green
- Test voltage oversheath insulation
- 5000 V
- Conductor cross-section
- 2 x 0,22 mm²
- Outer diameter
- 3.80 mm ±0.20 mm
- Cable length
- 100 m
- Application temperature
- -50...+180 °C
- Environmental data
- RoHS and REACH compliant
- Weight
- 2 kg
Due to various applications, which need reliable temperature measurement and a safe transfer of the resulting thermoelectric voltage in the mV range, our compensating cables are insulated with various materials, or the thermovoltage and cables are protected with braiding.